image 2 image 4
Skip Navigation Links
 Home 
 Congress Structure 
 Important Dates 
 Venue 
 Registration 
 Pre Registered 
 Abstracts 
 Scientific Program 
 Photo and Film Festival 
 Exhibition 
 Contact Us 
 Personal page 
 past Guest Speakers 
       XXIX Annual Congress of the Iranian Society of Ophthalmology        بـیــست و نهمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: Comparison of Conventional and Pattern Scanning Pan-retinal Photocoagulation on Diabetic Patients' visual field
Author(s): Mohamadreza Niyousha1, Mohamadhosein Ahoor1, Amir Abdollah Eftekhari 1, Sasan Jafari2, Narges Hassanpoor3
Presentation Type: Oral
Subject: Posterior Segment
Others:
Presenting Author:
Name: Narges Hassanpoor
Affiliation :(optional) Farabi Eye Hospital
E mail: nargeshassanpoor@gmail.com
Phone: 02155487865
Mobile: 09125709817
Purpose:

to compare visual field defects in two different methods of conventional pan retinal photocoagulation (PRP) and Pattern Scanning PRP in patients with proliferative diabetic or very severe non- proliferative diabetic retinopathy.

Methods:

Twenty patients with proliferative or very severe non-proliferative diabetic retinopathy were enrolled. Only patients with same severity score in both eyes were included. One eye underwent the Conventional PRP and the other eye Pattern Scanning PRP simultaneously. SITA Standard perimetry was repeated one month after the initial PRP and evaluated for visual field defects.

Results:

Pattern standard deviation (PSD) significantly increased in both pattern and conventional PRP groups within one month after PRP. There was no significant difference between the mean PSD values of the two groups before PRP and after one month of the follow-up.The mean deviation (MD) level significantly decreased in the conventional group after 1 month.

Conclusion:

Changes in visual acuity and visual field of patients between the two Pattern and conventional PRP methods did not show a significant difference but pattern PRP method causes less reduction of the overall sensitivity in the patient's visual field.

Attachment:





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات رزرو هتل
        مقالات
        برنامه کنگره
        جشنواره فیلم و عکس
        نمایشگاه
        تماس با ما
        صفحه شخصی
        جستجوی سخنران
        تور مجازی مجتمع سپید مشهد
        آرشیو کنگره سالهای گذشته
        آرشیو سخنرانان مهمان
 
ورود شرکت کنندگان
نام کاربری :
کلمه عبور :
  کلمه عبور خود را فراموش کرده ام.
Total Visits


Congress Count Down
Today Label
Last Month Label
Total Visitors Label