image 2 image 4
Skip Navigation Links
 Home 
 Congress Structure 
 Important Dates 
 Venue 
 Registration 
 Pre Registered 
 Abstracts 
 Scientific Program 
 Photo and Film Festival 
 Exhibition 
 Contact Us 
 Personal page 
 past Guest Speakers 
       XXIX Annual Congress of the Iranian Society of Ophthalmology        بـیــست و نهمین کنــگــره سـالیـانه انـجـمـن چـشـم پـزشـکی ایـــران
مقاله Abstract


Title: Perfluorocarbone May Change The Silicon Oil Specific Gravity
Author(s): pejvak azadi
Presentation Type: Oral
Subject: Posterior Segment
Others:
Presenting Author:
Name: Pejvak Azadi
Affiliation :(optional) kermanshah university of medical sciences
E mail: azadipe@yahoo.com
Phone: 08337291431
Mobile: 09126757827
Purpose:

To report a case in which Perflurocarbone ( DK-Line ) residuals changed the injected silicon oil specific gravity soon.

Methods:

A 46 year-old man was referred to the clinic due to the right eye pseudophakic rhegmatogenous retinal detachment since 5 days ago.

Results:

: At the presentation the vision was hand motion perception in the right eye. Funduscopy revealed nearly- total, macular involving retinal detachment with large superior retinal break and multiple peripheral small breaks. The left eye examinations were within normal limit. Two days later he was experienced pars plana vitrectomy with DK-Line injection and endolasering. During air-fluid exchange the retina slipped significantly, so DK-Line – silicon oil 5700 exchange was performed for him, trying to evacuate the DK-Line completely. One month later the vision had improved to 1/10, but it seemed that some DK-Line has not been completely removed from the eye. Retina was attached. Trying to lessen the DK-Line-induced retinal toxicity, he was scheduled for silicon oil, DK-Line removal. During the second surgery it was seen that the silicon oil specific gravity had changed completely to a denser- than- water liquid, necessitating deeply removal. The DK-Line removed too

Conclusion:

intraocular remained DK-Line could change the light silicon oil density, necessitating deep removal and emphasizing another reason for complete DK-Line removal.

Attachment:





Skip Navigation Links
        صفحه اصلی
        ساختار کنگره
        تاریخ های مهم
        مکان برگزاری
        ثبت نام
        ثبت نام شدگان
        اطلاعات رزرو هتل
        مقالات
        برنامه کنگره
        جشنواره فیلم و عکس
        نمایشگاه
        تماس با ما
        صفحه شخصی
        جستجوی سخنران
        تور مجازی مجتمع سپید مشهد
        آرشیو کنگره سالهای گذشته
        آرشیو سخنرانان مهمان
 
ورود شرکت کنندگان
نام کاربری :
کلمه عبور :
  کلمه عبور خود را فراموش کرده ام.
Total Visits


Congress Count Down
Today Label
Last Month Label
Total Visitors Label